Free sample for Thermal Fluid Oil Boiler - SZS Gas Fired Boiler – Taishan Group
Free sample for Thermal Fluid Oil Boiler - SZS Gas Fired Boiler – Taishan Group Detail:
SZS Oil Fired Boiler
Product Description
SZS series gas steam boiler is with D-type arrangement, natural recycling, double-drum water tube boiler. Longitudinal drum, full membrane wall structure, slightly positive pressure combustion. Furnace is wrapped by membrane wall, smoke enters the convection bank which is between the upper and lower drum from furnace exit, and then enters the tail heating surface -- steel spiral fin economizer.
SZS series gas steam boiler is designed and optimized to produce low pressure steam or hot water with rated evaporation capacity from 4 to 75 ton/hour and rated pressure from 0.7 to 2.5MPa. The design heat efficiency is up to 95%.
Features:
1. Body is not leakage, exhaust loss is little, thermal efficiency is high.
2. Compact structure, small installation size, and small investment.
3. Steam boilers adopts natural recycling and larger cross-section; hot-water boiler adopts ejector cycle, water circulation is safe and reliable.
4. With well-known, highly efficient burner and auxiliary equipment, fully automatic operation.
5. Perfect control system ensures the safe operation of the boiler.
Application:
SZS series gas steam boiler is widely used in chemical industry, paper making industry, textile industry, food industry, pharmaceuticals industry, heating industry, construction industry.
Specifications of SZS Gas Fired Hot Water Boiler | |||||||
Model | Rated Thermal Power (MW) | Rated Output Pressure (MPa) | Rated Output Temperature (°C) | Rated Input Temperature (°C) | Flue Gas Temperature (°C) | Fuel Consumption (m³/h) | Max Transport Dimension (mm) |
SZS4.2-1.0/95/70-Q | 4.2 | 1 | 95 | 70 | 155 | 459 | 5900x2700x3200 |
SZS4.2-1.0/115/70-Q | 4.2 | 1 | 115 | 70 | 164 | 460 | 5900x2700x3200 |
SZS5.6-1.0/95/70-Q | 5.6 | 1 | 95 | 70 | 155 | 611 | 7200x3000x3500 |
SZS5.6-1.0/115/70-Q | 5.6 | 1 | 115 | 70 | 164 | 614 | 7200x3000x3500 |
SZS7-1.0/95/70-Q | 7 | 1 | 95 | 70 | 155 | 764 | 7800x3400x3600 |
SZS7-1.0/115/70-Q | 7 | 1 | 115 | 70 | 164 | 767 | 7800x3400x3600 |
SZS10.5-1.0/115/70-Q | 10.5 | 1 | 115 | 70 | 161 | 1149 | 8500x3600x3600 |
SZS10.5-1.25/130/70-Q | 10.5 | 1.25 | 130 | 70 | 169 | 1156 | 8500x3600x3600 |
SZS14-1.0/115/70-Q | 14 | 1 | 115 | 70 | 161 | 1532 | 9200x3700x3700 |
SZS14-1.25/130/70-Q | 14 | 1.25 | 130 | 70 | 169 | 1541 | 9200x3700x3700 |
SZS21-1.25/130/70-Q | 21 | 1.25 | 130 | 70 | 168 | 2310 | 11000x3900x4600 |
SZS21-1.6/130/70-Q | 21 | 1.6 | 130 | 70 | 168 | 2310 | 11000x3900x4600 |
SZS29-1.25/130/70-Q | 29 | 1.25 | 130 | 70 | 168 | 3189 | 11200x4600x5200 |
SZS29-1.6/130/70-Q | 29 | 1.6 | 130 | 70 | 168 | 3189 | 11200x4600x5200 |
SZS46-1.6/130/70-Q | 46 | 1.6 | 130 | 70 | 168 | 5059 | 11800x5800x6600 |
SZS58-1.6/130/70-Q | 58 | 1.6 | 130 | 70 | 168 | 6379 | 12200x6000x8900 |
SZS64-1.6/130/70-Q | 64 | 1.6 | 130 | 70 | 168 | 7039 | 12500x6000x8900 |
SZS70-1.6/130/70-Q | 70 | 1.6 | 130 | 70 | 168 | 7698 | 12700x6200x9500 |
Remark | 1. Design efficiency is 92~95%. 2. LHV is based on 35588KJ/Nm3. |
Specifications of SZS Gas Fired Steam Boiler | |||||||
Model | Rated Evaporation Capacity (t/h) | Rated Steam Pressure (MPa) | Rated Steam Temperature (°C) | Feed Water Temperature (°C) | Flue Gas Temperature (°C) | Fuel Consumption (m³/h) | Max Transport Dimension (mm) |
SZS4-1.25-Q | 4 | 1.25 | 193 | 20 | 158 | 330 | 5200×2700×3200 |
SZS4-1.6-Q | 4 | 1.6 | 204 | 20 | 164 | 330 | 5200×2700×3200 |
SZS4-2.5-Q | 4 | 2.5 | 226 | 20 | 168 | 331 | 5200×2700×3200 |
SZS6-1.25-Q | 6 | 1.25 | 193 | 105 | 159 | 426 | 5900×2700×3200 |
SZS6-1.6-Q | 6 | 1.6 | 204 | 105 | 164 | 429 | 5900×2700×3200 |
SZS6-2.5-Q | 6 | 2.5 | 226 | 105 | 168 | 433 | 5900×2700×3200 |
SZS8-1.25-Q | 8 | 1.25 | 193 | 105 | 164 | 568 | 7200x3400x3500 |
SZS8-1.6-Q | 8 | 1.6 | 204 | 105 | 168 | 572 | 7200x3400x3500 |
SZS8-2.5-Q | 8 | 2.5 | 226 | 105 | 158 | 577 | 7200x3400x3500 |
SZS10-1.25-Q | 10 | 1.25 | 193 | 105 | 164 | 710 | 7800x3400x3600 |
SZS10-1.6-Q | 10 | 1.6 | 204 | 105 | 168 | 714 | 7800x3400x3600 |
SZS10-2.5-Q | 10 | 2.5 | 226 | 105 | 158 | 721 | 7800x3400x3600 |
SZS15-1.25-Q | 15 | 1.25 | 193 | 105 | 164 | 1064 | 8500x3600x3600 |
SZS15-1.6-Q | 15 | 1.6 | 204 | 105 | 168 | 1072 | 8500x3600x3600 |
SZS15-2.5-Q | 15 | 2.5 | 226 | 105 | 168 | 1081 | 8500x3600x3600 |
SZS20-1.25-Q | 20 | 1.25 | 193 | 105 | 158 | 1418 | 9200x3700x3700 |
SZS20-1.6-Q | 20 | 1.6 | 204 | 105 | 164 | 1428 | 9200x3700x3700 |
SZS20-2.5-Q | 20 | 2.5 | 226 | 105 | 168 | 1441 | 9200x3700x3700 |
SZS25-1.25-Q | 25 | 1.25 | 193 | 105 | 158 | 1773 | 11400x3700x3800 |
SZS25-1.6-Q | 25 | 1.6 | 204 | 105 | 164 | 1785 | 11400x3700x3800 |
SZS25-2.5-Q | 25 | 2.5 | 226 | 105 | 168 | 1801 | 11400x3700x3800 |
SZS30-1.25-Q | 30 | 1.25 | 193 | 105 | 158 | 2128 | 11000x3900x4600 |
SZS30-1.6-Q | 30 | 1.6 | 204 | 105 | 164 | 2142 | 11000x3900x4600 |
SZS30-2.5-Q | 30 | 2.5 | 226 | 105 | 168 | 2161 | 11000x3900x4600 |
SZS35-1.25-Q | 35 | 1.25 | 193 | 105 | 155 | 2477 | 11200x4600x5200 |
SZS35-1.6-Q | 35 | 1.6 | 204 | 105 | 160 | 2494 | 11200x4600x5200 |
SZS35-2.5-Q | 35 | 2.5 | 226 | 105 | 165 | 2516 | 11200x4600x5200 |
SZS40-1.25-Q | 40 | 1.25 | 193 | 105 | 155 | 2831 | 11200x4600x6000 |
SZS40-1.6-Q | 40 | 1.6 | 204 | 105 | 160 | 2851 | 11200x4600x6000 |
SZS40-2.5-Q | 40 | 2.5 | 226 | 105 | 165 | 2876 | 11200x4600x6000 |
SZS65-1.25-Q | 65 | 1.25 | 193 | 105 | 155 | 4601 | 11800x5800x6600 |
SZS65-1.6-Q | 65 | 1.6 | 204 | 105 | 160 | 4632 | 11800x5800x6600 |
SZS65-2.5-Q | 65 | 2.5 | 226 | 105 | 165 | 4673 | 11800x5800x6600 |
SZS75-1.25-Q | 75 | 1.25 | 193 | 105 | 155 | 5309 | 12200x6000x8900 |
SZS75-1.6-Q | 75 | 1.6 | 204 | 105 | 160 | 5345 | 12200x6000x8900 |
SZS75-2.5-Q | 75 | 2.5 | 226 | 105 | 165 | 5392 | 12200x6000x8900 |
Remark | 1. Design efficiency is 92~95%. 2. LHV is based on 35588KJ/Nm3. |
Product detail pictures:




Related Product Guide:
"Sincerity, Innovation, Rigorousness, and Efficiency" would be the persistent conception of our enterprise with the long-term to build with each other with consumers for mutual reciprocity and mutual advantage for Free sample for Thermal Fluid Oil Boiler - SZS Gas Fired Boiler – Taishan Group , The product will supply to all over the world, such as: Australia, Johannesburg, Sri Lanka, Our Company policy is "quality first, to be better and stronger, sustainable development" . Our pursuit goals is "for society, customers, employees, partners and enterprises to seek reasonable benefit". We aspirate to do cooperate with all different the auto parts manufacturers, repair shop, auto peer , then create a beautiful future! Thank you for taking time to browse our website and we would welcome any suggestions you may have that can help us to improve our site.

The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!